Leakage Tapping Detection Machine
Basic Attributes
- 型号 CMOTD
- 型号 CMOTD
- 型号 CMOTD
Models List
-
CMOTD-40A
-
CMOTD-60A
-
CMOTD-80A
-
CMOTD-100A
-
CMOTD-120A
-
CMOTD-140A
Description
The detection speed is fast and the efficiency is high, with accurate detection, significantly reducing the use of labor and saving labor costs.
Product Specification
| Item | CMOTD-40A | CMOTD-60A | CMOTD-80A | CMOTD-100A |
|---|---|---|---|---|
| Number of Detection Holes | 40 | 60 | 80 | 100 |
| Detection Type | Missing Punch, Missing Tapping, Hole Misalignment | Missing Punch, Missing Tapping, Hole Misalignment | Missing Punch, Missing Tapping, Hole Misalignment | Missing Punch, Missing Tapping, Hole Misalignment |
| Detection Method | Specialized Fixture, Two-Stage Detection | Specialized Fixture, Two-Stage Detection | Specialized Fixture, Two-Stage Detection | Specialized Fixture, Two-Stage Detection |
| Operating Interface | 5.7-inch HMI | 5.7-inch HMI | 8-inch HMI | 8-inch HMI |
| Machine Dimensions mm | 800*600 | 1000*800 | 1000*800 | 1200*1000 |
| Suitable Workpieces | Aluminum backplates under 22 inches | Aluminum backplates under 22 inches | Aluminum backplates under 32 inches | Aluminum backplates under 32 inches |
| Input Voltage | Single-phase 220VAC | Single-phase 220VAC | Single-phase 220VAC | Single-phase 220VAC |
| Input Air Pressure MPA | 0.6 | 0.6 | 0.6 | 0.6 |
| Hole Position Settings and Abnormality Indicators | Set via HMI | Set via HMI | Set via HMI | Set via HMI |
| Operating Mode | Single-machine/Networked operation | Single-machine/Networked operation | Single-machine/Networked operation | Single-machine/Networked operation |
| Machine & Fixture Connection | Quick Modular Design | Quick Modular Design | Quick Modular Design | Quick Modular Design |
| Item | CMOTD-120A | CMOTD-140A |
|---|---|---|
| Number of Detection Holes | 120 | 140 |
| Detection Type | Missing Punch, Missing Tapping, Hole Misalignment | Missing Punch, Missing Tapping, Hole Misalignment |
| Detection Method | Specialized Fixture, Two-Stage Detection | Specialized Fixture, Two-Stage Detection |
| Operating Interface | 10.4-inch HMI | 10.4-inch HMI |
| Machine Dimensions mm | 1500*1200 | 1600 *1300 |
| Suitable Workpieces | Aluminum backplates under 42 inches | Aluminum backplates under 50 inches |
| Input Voltage | Single-phase 220VAC | Single-phase 220VAC |
| Input Air Pressure MPA | 0.6 | 0.6 |
| Hole Position Settings and Abnormality Indicators | Set via HMI | Set via HMI |
| Operating Mode | Single-machine/Networked operation | Single-machine/Networked operation |
| Machine & Fixture Connection | Quick Modular Design | Quick Modular Design |